Further clinical support for LiDCO products

30 Jul 2014 07:00

RNS Number : 6711N
LiDCO Group Plc
30 July 2014
 



LiDCO Group Plc

("LiDCO" or the "Company")

 

Further clinical support for LiDCO products

 

New nurse-led study shows the benefits of haemodynamic optimisation using LiDCOplus

 

LiDCO Group Plc (AIM: LID), the cardiovascular monitoring company, announces that a new prospective observational trial covering a total of 264 cardiac surgery patients has been accepted for publication in the next edition of the Journal of Critical Care*. The study showed that the use of LiDCOplus significantly reduced the incidence of acute kidney injury (AKI), reduced the subsequent need for renal replacement therapy, and reduced the hospital length of stay.

 

Details of the study

The active treatment arm had post-operative stroke volume maximisation using the LiDCOplus which was compared to a treatment arm using standard of care.

 

The study evaluated the outcome of 123 cardiac surgery patients who had post-operative stroke volume maximisation Goal-Directed Therapy (GDT) using the LiDCOplus compared to 141 patients who had standard post-operative monitoring. The patients all had coronary artery bypass with or without aortic valve surgery. Importantly the intervention was nurse led in the cardiac intensive care unit (ICU) and consisted of fluid challenges to maximise stroke volume over an 8 hour period following admission to the ICU.

Although both groups received similar volumes of fluid, the authors agreed that the GDT group received the fluids earlier before haemodynamic compromise was observed in contrast to the control group who received fluids after signs of haemodynamic compromise. Importantly the incidence of AKI was significantly reduced in the GDT group with a total of 8 patients (6.5%) exhibiting AKI compared to 28 (19.9%) in the standard of care group. The median duration of hospital stay was 6 days in the GDT group compared to 7 days patients receiving standard of care.

 

The investigators also report that the GDT group had a low (3.3%) requirement for renal replacement therapy (RRT dialysis) compared to 10.6% in the standard of care group. In addition, the rate of readmissions to the ICU was reduced in the GDT group.

 

Commenting, Terry O'Brien, Chief Executive Officer of LiDCO, said: "This is an important study in a cardiac group of patients where the incidence of AKI is high averaging around 24%. AKI is associated with a high mortality rate of 7% - so avoiding it is very worthwhile clinically. Financially, the number of inpatients affected by AKI means that it has a major impact on healthcare resources. NICE (National Institute for Health and Care Excellence) has estimated that the costs to the NHS of AKI (excluding costs in the community) are between £434m and £620m per year, which is more than the costs associated with breast cancer, or lung and skin cancer combined*. The study clearly shows that avoidance of kidney compromise through using the LiDCO's fluid monitoring technology overseen by the ICU nursing team can reduce the incidence of post-operative AKI by 70%, which represents a significant saving to the NHS and improves patient outcomes."

· Thomson Rebekah, Meeran Hanif, Valencia Oswaldo, Al-Subaie Nawaf, Goal-Directed therapy following cardiac surgery and the incidence of acute kidney injury, Journal of Critical Care (2014), doi: 10.1016/j.jcrc.2014.06.011

· NICE Guidance CG169 Aug 2013: http://www.nice.org.uk/guidance/CG169/chapter/introduction

 

LiDCO Group Plc

www.lidco.com

Terry O'Brien (CEO)

Tel: +44 (0)20 7749 1500

Paul Clifford (Finance Director)

finnCap

Tel: +44 (0)20 7220 0500

Geoff Nash / Henrik Persson (Corporate Finance)

Stephen Norcross (Corporate Broking)

Walbrook PR Ltd

Tel: 020 7933 8780 or lidco@walbrookpr.com

Paul McManus

Mob: 07980 541 893

Lianne Cawthorne

Mob: 07584 391 303

 

About LiDCO Group Plc (www.lidco.com)

LiDCO is a supplier of non-invasive and minimally invasive hemodynamic equipment to hospitals used to monitor the amount of blood flowing around the body and ensure that vital organs are adequately oxygenated. LiDCO's products facilitate the application of hemodynamic optimisation protocols for high risk patients in both critical care units and in the operating theatre. 

 

Increasingly clinical studies are showing that the optimisation of patients' hemodynamic status in high risk patients produces better outcomes and reduced hospital stay. LiDCO's computer-based technology, developed at St Thomas' Hospital in London, has been shown to significantly reduce morbidity and complications, length of stay and overall costs associated with major surgery.

 

Key Products:

 

LiDCOplus: a computer-based platform monitor used in the Intensive Care Unit for real-time continuous display of hemodynamic parameters including cardiac output, oxygen delivery and fluid-volume responsiveness (PPV% and SVV%).

 

LiDCOrapid: a cardiac output monitor designed specifically for use in the operating theatre for fluid and drug management. The monitor enables anaesthetists to receive accurate and immediate feedback on the patient's fluid and hemodynamic status - a key measure of overall well-being before, during and after surgery. The LiDCOrapid provides:

 

· early and rapid warning of hemodynamic change to aid choice of therapeutic route: fluid or drug

· quantification of hemodynamic response

· guidance on effective delivery of fluids to ensure the right amount at the right time

 

LiDCOview: an easy-to-use graphical display of historical LiDCOplus and LiDCOrapid hemodynamic data.

 

LiDCO Unity Software: software incorporated into LiDCOrapid v2 that allows the LiDCOrapid monitor to co-display Covidien's level of consciousness parameter ('BISTM')* and add the convenience of CNSystem's continuous non-invasive blood pressure monitoring ('CNAP')**. This will address a growing requirement for non-invasive monitoring solutions that are more comprehensive and can effectively replace multiple single parameter monitors. 

 

*BISTM and Bispectral Index are trademarks of Covidien LP registered in the US and foreign countries.

* CNAPTM is a trademark of CNSystems Medizintechnik AG.

 

 

LiDCO monitors use single-patient disposables (sensors or smartcards) which provide an ongoing revenue stream.

 

LiDCO Distribution Network:

LiDCO sells directly to hospitals in the UK and USA and through a network of specialty critical care and anaesthesia distributors in the rest of the world.

 

LiDCO's marketing office is in Cambridge, its manufacturing facility and headquarters are in London and its shares are traded on AIM.

 

 

This information is provided by RNS
The company news service from the London Stock Exchange
 
END
 
 
NRAPGUUGMUPCGRB
Date   Source Headline
29th Mar 20167:00 amRNSRegulatory approval in China
24th Mar 20167:00 amRNSMaster distribution agreement & other distributors
15th Mar 20167:00 amRNSLaunching the new LiDCOunity at ISICEM Brussels
4th Mar 20164:31 pmRNSHolding(s) in Company
2nd Mar 20165:06 pmRNSBlock Listing Review
8th Feb 20167:00 amRNSTrading update
2nd Feb 20163:52 pmRNSHolding(s) in Company
23rd Nov 20157:00 amRNSMaster distribution agreement
16th Nov 20154:35 pmRNSDirector's Dealing
13th Oct 20158:30 amRNSUS purchasing agreement with US hospitals group
13th Oct 20157:00 amRNSHalf Yearly Report
23rd Sep 201510:03 amRNSNotice of Results
2nd Sep 20157:00 amRNSTrading update and notice of results
17th Aug 20157:00 amRNSFormal appointment of Chief Executive Officer
31st Jul 20157:00 amRNSBlock Listing Review
15th Jun 20152:27 pmRNSBoard appointment and grant of share options
11th Jun 20157:00 amRNSJapan reimbursement for LiDCOrapidv2 disposables
13th May 201511:45 amRNSResult of AGM
6th May 20157:01 amRNSCEO and Board Appointment
5th May 20151:32 pmRNSPosting of Annual Report & Notice of AGM
23rd Apr 20157:00 amRNSLiDCO data presented at London Forum
14th Apr 20157:00 amRNSHolding in Company
1st Apr 201512:49 pmRNSDirector/PDMR Shareholding
31st Mar 20157:01 amRNSLIDCOrapid v2 cleared for sale in Japan
31st Mar 20157:00 amRNSFinal Results
17th Mar 20157:00 amRNSShowcasing Portable LiDCO Stand System at ISICEM
10th Mar 20157:03 amRNSNotice of Results
2nd Mar 20156:14 pmRNSHolding(s) in Company
17th Feb 20157:00 amRNSFurther clinical support for LiDCOrapid
12th Feb 20157:00 amRNSTrading update and notice of results
30th Jan 201512:20 pmRNSBlock listing review
17th Dec 20142:39 pmRNSHolding(s) in Company
1st Dec 20142:39 pmRNSHolding(s) in Company
17th Nov 20147:00 amRNSFurther clinical support for LiDCOrapid
12th Nov 20145:15 pmRNSHolding(s) in Company
7th Nov 201412:03 pmRNSHolding(s) in Company
3rd Nov 20145:49 pmRNSHolding(s) in Company
16th Sep 20147:01 amRNSBoard Announcement
16th Sep 20147:00 amRNSHalf Yearly Report
21st Aug 201411:39 amRNSNotice of Results
18th Aug 20147:00 amRNSTrading update
31st Jul 20141:46 pmRNSBlock Listing Review
30th Jul 20147:00 amRNSFurther clinical support for LiDCO products
11th Jun 201412:45 pmRNSResult of AGM
11th Jun 201411:49 amRNSResult of AGM
11th Jun 20147:00 amRNSAGM Statement
23rd May 20141:51 pmRNSPosting of Annual Report & Notice of AGM
22nd May 20144:01 pmRNSHolding(s) in Company
21st May 20147:00 amRNSMonitors Link with NantHealth's DeviceConX System
20th May 20147:00 amRNSResults of the OPTIMISE study

Due to London Stock Exchange licensing terms, we stipulate that you must be a private investor. We apologise for the inconvenience.

To access our Live RNS you must confirm you are a private investor by using the button below.

Login to your account

Don't have an account? Click here to register.

Quickpicks are a member only feature

Login to your account

Don't have an account? Click here to register.