Certs and testing (1 of 2)18 Jan 2024 15:34
@BigDom1, I appreciate there are MANY RNSs and it can be hard to spot what you are looking for at any given moment. I trawled back for you, I may have missed something but this is what I've found so far:
9th Oct RNS (FX fire extinguisher and sprinkler fluid)
"Zenova Group PLC (AIM: ZED) , the innovative fire suppression and interdiction solutions Company, is excited to announce that it has been informed by MPA Dresden institute, a European Union-recognised certification centre, that both the Company's Zenova FX fluid used in all of Zenova fire extinguishers as well as the 6 and 9 litre fire extinguishers have all successfully completed the battery of regulation EN3-7 tests required for European certification. The official test results confirmed 34A, 113B, 75F and E for the 6 litre and 43A, 183B, 75F and E for the 9 litre fire extinguisher.
The formal certificates are expected to be received by October month-end which will then allow Zenova to market its premier products to retail and industrial customers requiring the highest certifications.
In addition, the Company is likewise pleased that it has just received its inaugural order for its FX 6 litre fire extinguisher immediately upon this news.
Thomas Melchior, CEO of the Zenova Group, commented, "Passing EN3-7 certification for both our fluids and extinguishers, is clearly a major milestone in the Company's short history. The team have been working hard to create distinctive products in the marketplace and gaining EN3-7 certification is a crucial endorsement of that effort and further supports the Company's growing competitive advantage in the marketplace." "
RNS 30th August (Fire Protection paint)
"Zenova Group PLC (AIM: ZED), is pleased to announce a further major development in the certification process of the Company's products, as Zenova's FP fire protection, intumescent paint has successfully been fire tested by BRE. This latest certification will directly impact Zenova's efforts to supply the construction market for Zenova FP applications for fire protection on steel.
Zenova FP fire resistance tested
Indicative Fire Resistance Tests were performed by the independent testing house BRE using BS476-20 and BS476-21:1987 testing standards.
Tests were also carried out with Zenova FP intumescent coating applied to various loaded and unloaded I-section steel columns and fire resistance tests were performed in accordance with EN 13381-8:2013."
(and there is an image of the test results on the RNS)
continued....