Further clinical support for LiDCOrapid

17 Feb 2015 07:00

RNS Number : 0543F
LiDCO Group Plc
17 February 2015
 

LiDCO Group Plc

("LiDCO" or the "Company")

 

LiDCOrapid technology shown to be quickest to detect blood loss

 

LiDCO Group Plc (AIM: LID), the cardiovascular monitoring company, welcomes the publication in the journal Anaesthesia of a study of the leading minimally invasive cardiac output devices tested ability to detect blood loss in awake volunteers entitled "Evaluation of the utility of the Vigileo FloTracTM, LiDCOTM, USCOM and CardioQTM to detect hypovolaemia in conscious volunteers: a proof of concept study."

 

It is important to quickly detect and reverse decreased blood volume (hypovolaemia). If undetected and untreated or treated late, low blood volume will lead to poor clinical outcomes post operatively. However, detection is particularly challenging in the conscious, spontaneously breathing patient in the emergency room and post-surgery where fluid responsiveness parameters are not usable.

 

A research group in Australia evaluated the performance of minimally invasive cardiac output monitors to detect blood loss in volunteers subjected to blood removal of 2.5% blood volume aliquots to a total of 20% blood volume removed. The devices tested were LiDCO's LiDCOrapid, Edwards Vigileo FloTracTM, and the USCOM and Deltex CardioQTM Doppler based devices.

 

A statistically significant difference from baseline stroke volume (a measure of the circulation ability to fill the heart effectively) was detected quickest by the LiDCO device after only 2.5% blood loss compared to the other devices where blood loss was detected less quickly. The USCOM device detected hypovolemia later than LiDCO, after three times as much blood had been lost (7.5%) and the two other monitors, Deltex CardioQ and Edwards FloTrac, after a loss of 12.5%.

 

Commenting, Terry O'Brien, Chief Executive Officer of LiDCO, said: "Hypovolemia is not possible to detect early enough using the traditional parameter of blood pressure. The precision to detect small changes in blood volume status is valuable in many clinical settings. Unseen blood loss can occur in the emergency room, surgery and in intensive care settings. Earliest detection must be the goal. LiDCO monitors have been shown by this excellent comparative study to be the quickest at detecting blood loss. This performance gives our customers the best chance of avoiding excessive blood loss and guiding fluid replacement."

 

 

* Paper Referenced: Evaluation of the utility of the Vigileo FloTracTM, LiDCOTM, USCOM and CardioQTM to detect hypovolaemia in conscious volunteers: a proof of concept study. Anaesthesia 2015, 70, 142-149

 

 

For further information, please contact:

 

LiDCO Group Plc

www.lidco.com

Terry O'Brien (CEO)

Tel: +44 (0)20 7749 1500

Paul Clifford (Finance Director)

 

 

 

finnCap

Tel: +44 (0)20 7220 0500

Geoff Nash / James Thompson (Corporate Finance)

 

Stephen Norcross (Corporate Broking)

 

 

 

Walbrook PR Ltd

Tel: 020 7933 8780 or lidco@walbrookpr.com

Paul McManus

Mob: 07980 541 893

Lianne Cawthorne

Mob: 07584 391 303

 

 

 

 

About LiDCO Group Plc (www.lidco.com)

LiDCO is a supplier of non-invasive and minimally invasive hemodynamic equipment to hospitals used to monitor the amount of blood flowing around the body and ensure that vital organs are adequately oxygenated. LiDCO's products facilitate the application of hemodynamic optimisation protocols for high risk patients in both critical care units and in the operating theatre. 

 

Increasingly clinical studies are showing that the optimisation of patients' hemodynamic status in high risk patients produces better outcomes and reduced hospital stay. LiDCO's computer-based technology, developed at St Thomas' Hospital in London, has been shown to significantly reduce morbidity and complications, length of stay and overall costs associated with major surgery.

 

Key Products:

 

LiDCOplus: a computer-based platform monitor used in the Intensive Care Unit for real-time continuous display of hemodynamic parameters including cardiac output, oxygen delivery and fluid-volume responsiveness (PPV% and SVV%).

 

LiDCOrapid: a cardiac output monitor designed specifically for use in the operating theatre for fluid and drug management. The monitor enables anaesthetists to receive accurate and immediate feedback on the patient's fluid and hemodynamic status - a key measure of overall well-being before, during and after surgery. The LiDCOrapid provides:

 

· early and rapid warning of hemodynamic change to aid choice of therapeutic route: fluid or drug

· quantification of hemodynamic response

· guidance on effective delivery of fluids to ensure the right amount at the right time

 

LiDCOview: an easy-to-use graphical display of historical LiDCOplus and LiDCOrapid hemodynamic data.

 

LiDCO Unity Software: software incorporated into LiDCOrapid v2 that allows the LiDCOrapid monitor to co-display Covidien's level of consciousness parameter ('BISTM')* and add the convenience of CNSystem's continuous non-invasive blood pressure monitoring ('CNAP')**. This will address a growing requirement for non-invasive monitoring solutions that are more comprehensive and can effectively replace multiple single parameter monitors. 

 

*BISTM and Bispectral Index are trademarks of Covidien LP registered in the US and foreign countries.

* CNAPTM is a trademark of CNSystems Medizintechnik AG.

 

LiDCO monitors use single-patient disposables (sensors or smartcards) which provide an ongoing revenue stream.

 

LiDCO Distribution Network:

LiDCO sells directly to hospitals in the UK and USA and through a network of specialty critical care and anaesthesia distributors in the rest of the world.

 

LiDCO's marketing office is in Cambridge, its manufacturing facility and headquarters are in London and its shares are traded on AIM.

This information is provided by RNS
The company news service from the London Stock Exchange
 
END
 
 
NRALLFIDFAIRLIE
Date   Source Headline
26th Apr 20107:00 amRNSPreliminary Results
3rd Mar 20104:25 pmRNSSale of Employee Benefit Trust shares
25th Feb 20107:00 amRNSPre-close trading update & notice of Results & AGM
2nd Feb 20107:00 amRNSLiDCO featured in case study from Intel
4th Nov 20097:00 amRNSNOTIFICATION OF MAJOR INTEREST IN SHARES
29th Oct 20097:00 amRNSInterim Results
19th Oct 20097:00 amRNSAspect launches LiDCOrapid at ASA annual meeting
5th Oct 20097:00 amRNSNotice of Results
5th Oct 20097:00 amRNSWelcomes Covidien acquisition of Aspect Medical
1st Sep 20097:00 amRNSLIDCOrapid chosen for UK OPTIMISE study
19th Aug 20097:00 amRNSTrading Statement
29th Jul 20097:00 amRNSExclusive US-wide distribution agreement
16th Jul 20097:00 amRNSSoftware upgrade for the LiDCOrapid
7th Jul 20091:48 pmRNSIssue of Equity
24th Jun 20095:00 pmRNSTR-1: Notification of Major Interests in Shares
24th Jun 200912:08 pmRNSResult of AGM
28th May 20094:15 pmRNSGrant of Share Options
22nd May 20095:11 pmRNSTR-1: Notifications of Major Interests in Shares
22nd May 20097:00 amRNS2009 Annual Report and Accounts
21st May 20097:00 amRNSIssue of Equity
21st Apr 20097:00 amRNSFinal Results
16th Apr 20097:00 amRNSLiDCO Extends Collaboration With BD
6th Apr 20097:00 amRNSChange of Adviser
10th Mar 20097:00 amRNSDistribution expansion
3rd Mar 200912:47 pmRNSHolding(s) in Company
2nd Mar 20097:00 amRNSNotice of Results and AGM
5th Feb 20094:13 pmRNSHolding(s) in Company
13th Jan 20097:00 amRNSDistribution expansion
30th Oct 20087:01 amRNSInterim Results
30th Oct 20087:00 amRNSLiDCO chosen for clinical trial
28th Oct 20087:00 amRNSDuke University submits US$250,000 order
14th Aug 20087:00 amRNSNew Loan Arrangement and Noti
29th Jul 20087:00 amRNSUS distribution agreement
4th Jul 200812:23 pmRNSHolding(s) in Company
25th Jun 200811:29 amRNSResult of AGM
19th Jun 20087:00 amRNSClinical Evidence
30th May 20087:00 amRNSAnnual Report and Accounts
28th Apr 20084:47 pmPRNDirector/PDMR Shareholding
25th Apr 200811:27 amRNSGrant of Share Options
24th Apr 20087:01 amRNSPreliminary Results
24th Apr 20087:01 amRNSFinance Director Appointment
21st Apr 20087:00 amRNSLaunch of LiDCOrapid Monitor
4th Mar 20087:00 amPRNPreview at World Congress
28th Feb 20087:00 amPRNTrading Update
26th Feb 20087:00 amPRNLiDCOview Pro Launch
25th Feb 20087:00 amPRNNotice of Results
30th Jan 20087:00 amPRNCanadian Distribution Agreement
31st Dec 20079:19 amRNSChange of Adviser
13th Dec 200711:44 amPRNGrant of Options
12th Dec 20077:00 amPRNResult of General Meeting

Due to London Stock Exchange licensing terms, we stipulate that you must be a private investor. We apologise for the inconvenience.

To access our Live RNS you must confirm you are a private investor by using the button below.

Login to your account

Don't have an account? Click here to register.

Quickpicks are a member only feature

Login to your account

Don't have an account? Click here to register.